![]() ![]() ![]() Construction documents for a project shall be fully coordinated and of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in sufficient detail pertinent data and features of the building, building systems and equipment as herein governed. Electronic media documents are permitted to be submitted in accordance with department procedures. ![]() An alteration that replaces only the bulb and ballast within the existing luminaires in a space, provided that such alteration does not increase the installed interior lighting power.Ĭonstruction documents shall be drawn to scale upon suitable material.An alteration that replaces less than 20 percent of the luminaires in a space in residential building or less than 10 percent of the luminaires in a space in a commercial building, provided that such alteration does not increase the installed interior lighting power.Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates a conditioned space from the exterior shall not be removed.Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. Reroofing where neither the sheathing nor the insulation is exposed.Alterations, renovations or repairs to walls and floors in cases where the existing structure is without framing cavities and no new framing cavities are created.Alterations, renovations or repairs to roof/ceiling, wall or floor cavities, including spaces between furring strips, provided that such cavities are insulated to the full existing cavity depth with insulation having a minimum nominal value of R-3.0/inch (R-2.0/ cm).Glass-only replacements in an existing sash and frame, provided that the U-factor and the solar heat gain coefficient ( SHGC) shall be equal to or lower than before the glass replacement.Storm windows installed over existing fenestration.This code shall not apply to the alterations of existing buildings set forth in items 1 through 8, provided that the alteration will not increase the energy usage of the building: Such state publications include (i) Chapters 1, 2, 3, 4, 5 and 6 of the publication entitled the 2020 Energy Conservation Construction Code of New York State ("ECCCNYS") and (ii) the referenced standards incorporated by reference in subdivision (b) of 19 NYCRR Section 1240.5. The provisions of the NYCECC for residential buildings are reflected in the state publications incorporated by reference in 19 NYCRR Section 1240.5, as amended by Sections 28-1001.2.1, 28-1001.2.2 and 28-1001.2.3 of the Administrative Code.Such state publications include (i) Chapters 1, 2, 3, 4, 5 and 6 of the publication entitled the 2020 Energy Conservation Construction Code of New York State ("ECCCNYS") (ii) the October 2016 edition of Energy Standard for Buildings Except Low-Rise Residential Buildings ("ASHRAE 90.1-2016"), as amended by 19 NYCRR Section 1240.3 and (iii) reference standards incorporated by reference in subdivision (c) of 19 NYCRR Section 1240.4. The provisions of the NYCECC for commercial buildings are reflected in the state publications incorporated by reference in 19 NYCRR Sections 1240.4, as amended by Sections 28-1001.2.1, 28-1001.2.2 and 28-1001.2.3 of the Administrative Code. ![]() Reflecting these amendments to the New York State Energy Conservation Construction Code, the NYCECC is divided into provisions relevant to commercial buildings and provisions relevant to residential buildings as follows: The New York City Energy Conservation Code ("NYCECC") is comprised of the New York State Energy Conservation Construction Code with amendments as enacted into law by the city. ![]()
0 Comments
Leave a Reply. |